    ICU病房設備:ICU設有監護站,直接觀察所有監護的病床。每床位的占地面積為15~18㎡,床位間用玻璃或布簾相隔。ICU的設備必須配有床邊監護儀、監護儀、多功能呼吸治療機、麻醉機、心電圖機、除顫儀、起搏器、輸液泵、微量注射器、處于備用狀態的吸氧裝置、氣管插管及氣管切開所需急救器材。在條件較好的醫院,還配有血氣分析儀、微型電子計算機、腦電圖機、B超機、床旁X線機、血液透析器、動脈內氣囊反搏器、血尿常規分析儀、血液生化分析儀等。
    ICU ward equipment: The ICU has a central monitoring station that directly observes all monitored beds. The floor area of each bed is 15-18 square meters, and the beds are separated by glass or cloth curtains. The equipment of ICU must be equipped with bedside monitor, central monitor, multi-functional respiratory therapy machine, anesthesia machine, electrocardiograph, defibrillator, pacemaker, infusion pump, micro injector, oxygen inhalation device in standby state, Tracheal intubation and first-aid equipment required for tracheotomy. In hospitals with good conditions, there are also blood gas analyzers, microcomputers, Electroencephalography machines, B-ultrasound machines, bedside X-ray machines, blood dialyzers, intra arterial balloon counterpulsators, routine blood and urine analyzers, blood biochemical analyzers, etc.
    此外,重癥醫學及急診學中還有小兒重癥監護病房(PICU);新生兒重癥監護病房(NICU);內科重癥監護病房(MICU);心血管重癥監護病房(CCU);心臟外科重癥監護病房(CICU);急診重癥監護病房(EICU)神經外科重癥監護( Neurosurgical intensive care unit,NSICU) 。
    In addition, there is a pediatric intensive care unit (PICU) in Intensive care medicine and emergency medicine; Neonatal Intensive Care Unit (NICU); Internal Medicine Intensive Care Unit (MICU); Cardiovascular Intensive Care Unit (CCU); Cardiac surgery Intensive Care Unit (CICU); Emergency Intensive Care Unit (EICU) Neurosurgery intensive care unit (NSICU).
    ICU重癥監護室建設要求:
    Construction requirements for ICU intensive care unit:
    、醫院ICU潔凈室的病床數量一般按全院總床位的3~5%為宜設置,每個ICU 管理單元以8到12張床位為宜;床位使用率以65~75%為宜。
    The number of beds in the clean room of the hospital's ICU is generally 3-5% of the total hospital beds, and each ICU management unit should have 8-12 beds; The bed utilization rate should be between 65% and 75%.
    2、地理位置選擇上方便患者轉運、檢查和治療的區域,并考慮以下因素:接近主要服務對象病區、手術室、影像學科、化驗室和血庫等,在橫向無法實現“接近時,應該考慮樓上樓下的縱向接近。
    2. Geographically, select areas that are convenient for patient transportation, examination, and treatment, and consider the following factors: proximity to the main service target ward, operating room, imaging discipline, laboratory, and blood bank, etc., which cannot be achieved horizontally; When approaching, consideration should be given to the vertical approach of the upper and lower floors.
    ,層流手術室裝修
    3、ICU開放式病床每床的占地面積為15~18M2;每個ICU更少配備一個單間病房,面積為18~25M2。每個ICU中的正壓和負壓隔離病房的設立,通常配備負壓隔離病房1~2間。
    3. The open hospital bed in the ICU covers an area of 15-18M2 per bed; Each ICU should be equipped with at least one single room ward with an area of 18-25M2. The positive and negative pressure Isolation ward in each ICU are usually equipped with 1-2 negative pressure Isolation ward.
    4、ICU的基本輔助用房包括醫師辦公室、主任辦公室、工作人員休息室、工作站、治療室、配藥室、儀器室、更衣室、清潔室、污廢物處理室、值班室、盥洗室等。有條件的ICU可配置其他輔助用房,包括示教室、家屬接待室、實驗室、營養準備室等。輔助用房面積與病房面積之比應達到1.5:1以上。
    4. The basic auxiliary rooms in the ICU include the physician's office, director's office, staff rest room, central workstation, treatment room, dispensing room, instrument room, changing room, cleaning room, waste disposal room, duty room, washroom, etc. ICUs with conditions can be equipped with other auxiliary rooms, including classrooms, family reception rooms, laboratories, nutrition preparation rooms, etc. The ratio of auxiliary room area to ward area should be above 1.5:1.
    5、ICU的整體布局應該使放置病床的醫療區域、醫療輔助用房區域、污物處理區域和醫務人員生活輔助用房區域等有相對的獨立性,以減少彼此之間的互相干擾并有利于感染的控制。
    5. The overall layout of the ICU should ensure relative independence in the medical area where the hospital bed is placed, the medical auxiliary room area, the sewage treatment area, and the medical staff living auxiliary room area, in order to reduce mutual interference and facilitate infection control.
    6、醫院ICU潔凈室應具備良好的通風、采光條件,有條件者更好裝配氣流方向從上到下的空氣凈化系統,能獨立控制室內的溫度和濕度。醫療區域內的溫度應維持在(24±1.5)℃左右。每個單間的空氣調節系統應該獨立控制。安裝足夠的感應式手設施和手部消毒裝置,單間每床1套,開放式病床至少每2床1套。
    6. The ICU clean room in a hospital should have good ventilation and lighting conditions. If possible, it is best to install an air purification system with airflow direction from top to bottom, which can independently control the indoor temperature and humidity. The temperature in the medical area should be maintained at around (24± 1.5) ℃. The air conditioning system of each single room should be independently controlled. Install sufficient inductive hand facilities and hand disinfection devices, with 1 set per bed in a single room and at least 1 set per 2 beds in an open hospital bed.
    7、ICU要控制好人流和物流要有合理的包括人員流動和物流在內的醫療流向,更好通過不同的進出通道實現,以限度減少各種干擾和交叉感染。
    7. ICU should control the flow of people and logistics, and have a reasonable medical flow, including personnel flow and logistics, preferably through different entry and exit channels to minimize various interferences and cross infections.
    8、ICU病房建筑裝飾必須遵循不產塵、不積塵、耐腐蝕、防潮防霉、防靜電、容易清潔和符合防火要求的總原則。
    8. The decoration of ICU ward buildings must follow the general principles of no dust production, no dust accumulation, corrosion resistance, moisture and mold resistance, anti-static, easy cleaning, and compliance with fire protection requirements.
    9、ICU的設計要求應該滿足提供醫護人員便利的觀察條件和在必要時盡快接觸病人的通道。
    9. The design requirements of the ICU should meet the requirements of providing convenient observation conditions for medical staff and providing access to patients as soon as necessary.
    10、ICU病房應安靜除了患者的呼叫信號、監護儀器的報警聲外,電話鈴聲、打印機等儀器發出的聲音等均屬于ICU的噪音。在不影響正常工作的情況下,這些聲音應盡可能減少到更小的水平。根據噪音協會的建議,ICU白天的噪音更好不要超過45分貝(A),傍晚40分貝(A),夜晚20分貝(A)。地面覆蓋物、墻壁和天花板應該盡量采用高吸音的建筑材料。
    10. The ICU ward should be quiet. Except for the patient's call signal and the alarm sound of the monitoring instrument, the Ringtone, the sound of the printer and other instruments are all ICU noises. These sounds should be minimized as much as possible without affecting normal operation. According to the recommendations of the International Noise Association, it is best not to exceed 45 decibels (A) during the day, 40 decibels (A) in the evening, and 20 decibels (A) at night in the ICU. Floor coverings, walls, and ceilings should be made of high sound-absorbing building materials as much as possible.
    本文由重癥監護室裝修為您提供,我們的網站是:http://www.sdyhrs.com/我們將以全心全意的熱情為您提供服務,歡迎您的訪問
    This article is provided by the decoration of the intensive care unit for you. Our website is: http://www.sdyhrs.com/ We will provide you with wholehearted enthusiasm and welcome your visit
    • 電話:0531-87568508
    • 手機:18653128690
    • 地址:濟南市槐蔭區鑫苑世家公館2號樓2603室
    • 郵箱:jnyhrs@163.com
    山東凈之源凈化工程有限公司 備案:魯ICP備09012422號-1 技術支持:網站建設·推廣運營 網站地圖 XML TXT

    截屏,微信識別二維碼

    微信號:18653128690

    美女露\u00100的奶头无挡网站,他用嘴巴含着我奶头好舒服,手伸进内衣使劲揉搓奶头漫画,美女露\u00100的奶头无挡挡
  • <nav id="44ioa"></nav>
  • <menu id="44ioa"></menu>